IRA-90 is a 90W AC to DC 4-pin mini-DIN industrial power adaptor compatible with PoE switch, that can operate between temperatures -30°C to 70°C (-22°F-158°F). The cable is 120 cm long from the power adaptor to the connector. It is a class I power adaptor that brings protection from short circuits, overload, over-voltage, and over-temperature protection. This power adapter is compliant with EISA 2007/DoE, NR Can, AU/NZ MEPS, EU ErP, and CoC Version 5. It has the highest level of energy efficiency (level VI) highest level of efficiency to specific minimum active average efficiency, and no-load power levels.
Output | DC Voltage | 48V | ||
Rated Current | 1.87A | |||
Rated Power (max.) | 90W | |||
Input | Voltage Range | 90 ~ 264VAC 127 ~ 370VDC | ||
Frequency Range | 47 ~ 63Hz | |||
AC Current (Typ.) | 1.3A / 115VAC 0.6A / 230VAC | |||
Protection | Overload | 110 ~ 150% rated output power Protection type: Hiccup mode, recovers automatically after fault condition is removed |
||
Over Voltage | 105 ~ 135% rated output voltage Protection type: Shut down o/p voltage, re-power on to recover |
|||
Over Temperature | Shut down o/p voltage, re-power on to recover | |||
Environment | Working Temperature | -30 ~ +70℃(Refer to "Derating Curve") | ||
Working Humidity | 20% ~ 90% RH non-condensing | |||
Storage Temperature, Humidity | -40 ~ +85℃, 10 ~ 95% RH | |||
SAFETY & EMC |
Safety Standards | EN55032(CISPR32),FCC PART 15 / CISPR22 CAN ICES-3(B)/NMB-3(B), CNS13438, GB17625.1 EAC TP TC 020, MSIP KN32 EN61000-3-2 GB9254, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11 |
||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A | |||
Others | Dimension (WxHxD) | 60 x 32 x 145 mm (2.36 x 1.26 x 5.7 in) | ||
Packing | 0.45Kg; 30pcs/14.05Kg/1CUFT |
Ordering Information
Model | Description |
---|---|
IRA-90 | 90W, 48V Industrial Grade AC Power Adapter |
*Specifications subject to change without prior notice.